Table 3-2. Functional Test Procedures - Continued
Table 3-2. Functional Test Procedures - Continued

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  38    39    40    41    42  43  44    45    46    47    48  
img
TM 3-6665-329-13&P
Table 3-2. Functional Test Procedures (Cont)
Test
Procedure
Test
No.
Adjust variable power supply to 36 volts dc.
6
SYNC PULSE Lamp
c.
(cont)
Count the number of flashes of SYNC PULSE
d.
lamp in a 10 second period. If the SYNC
PULSE lamp flashes approximately 6 times
1 every 10 seconds, continue testing. If
not, refer to Troubleshooting paragraph
3-7.3.
Power OFF.
e.
Disconnect jumper wire between test set point E
f.
and socket 3.