LOW PRESSURE HEATING BOILER ASSEMBLY. - Continued
COMBUSTION MOTOR MOUNTING ASSEMBLY. - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  243    244    245    246    247  248  249    250    251    252    253  
img
TM 3-4230-209-30&P
2-242
2-54. COMBUSTION MOTOR MOUNTING ASSEMBLY.
This task covers:
c. Reassembly
a. Disassembly
b. Repair
INITIAL SETUP
Equipment Condition
Tools and Special Tools
Combustion motor mounting assembly removed from low pressure heater
Automotive Maintenance and Repair Field Maintenance
boiler assembly.
Shop Equipment, Basic, Less Power (SC 4910-95-CL-A31)
REMARKS
LOCATION/lTEM
ACTION
Combustion Motor
Mounting Assembly/
Loosen setscrew (1) from centrifugal fan impeller (2). Remove four
Setscrew (1)
machine screws (3), internal tooth lock washers (4), and direct current
Centrifugal fan impeller (2)
motor (5) from motor mounting plate (6).
Machine screw (3)
Internal tooth lock
washer (4)
Direct current motor (5)
Motor mounting plate (6)