Inspection Standard
Item
Inspection Standard
Item
Pump
Pump body must not be cracked. Check that
Must function properly.
pump has been drained.
Plumbing
Must be free of leaks.
Battery
See TM 9-6140-200-14.
Must be free of leaks.
Must be packaged and taped to the top of pump-
Technical Publications
ing unit.
Belts must not be cracked or glazed. Check belts
for proper tension.
Tools
Must be present and in good condition.
INSPECTION STANDARD FOR WATER HEATER
Item
Inspection Standard
Inspection Standard
Item
Must be free of rust, cracks, breaks, or stripped
Lifting and Tie-down
No stripped threads
Bolts and Screws
Eyes
threads.
Must be tight.
Rivets
Hoses
Hoses and fittings must not be deformed or bro-
ken.
No loose or damaged connectors, cut or worn insu-
Electrical Wiring and
lation, broken wires or kinks.
Cables
Contol Panel
All valves, switches, and knobs must be operable.
The glass windows on the gages must not be
Welded joints must not show signs of separation or
Welds
broken.
failure.
Must be free of leaks,
Must be present, legible, and secure
Instruction and
Nameplates
Boiler must be free of leaks. The spark arrestor
must be present and free of damage. Nozzle and
Check that all required MWO's have been applied
MWO's
screen must be clean.
and are properly recorded. (See DA PAM 738-750.)
Tools
Must be present and in good condition
Painted surfaces must be in good condition and
Paint
free of bare spots, rust, and peeling.