Position the strap (5) over the rear section of electrical cable clamp (2),
Strap (5)
insert two screws (6) through the strap and into electrical cable clamp (2)
Screw (6)
tapped holes, and tighten.
Lug terminal (7)
Hole (8)
Strip and cut the other end of electrical power cable (1) to the lengths
shown in the illustration. Install two lug terminals (7) on power cable (1) so
its bare wires just protrude through the lug terminal barrel. Using proper
tools, crimp lug terminals (7) to power cable (1).
between lug terminal (7) on white wire and the outside of electrical plug
connector (3). The multimeter should read nearly zero ohms. Check from
lug terminal (7) on black wire to electrical plug connector (3) contact pin
with the multimeter. The multimeter should read nearly zero ohms.
Using a multimeter set to highest X setting, zero the meter and measure
the resistance between the electrical plug connector (3) contact pin and
the outer shell. The multimeter should read near infinite resistance.
Using silicone compound, fill electrical plug connector (3) rear section
through the small hole (8) on the side and let it dry.
TM 3-4230-209-30&P
2-187