END PANEL.
FRONT PANEL.

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  171    172    173    174    175  176  177    178    179    180    181  
img
2-170
TM 3-4230-209-30&P
2-34. END PANEL.
REMARKS
ACTION
LOCATION/lTEM
End Panel/
Retaining ring (1)
Remove retaining rings (1), turnlock fastener stud assemblies (2), and
Turnlock fastener stud
turnlock fastener eyelets (3), as necessary.
assemblies (2)
Turnlock fastener
Scrape off and discard old pressure sensitive tape (4) from end panel.
eyelets (3)
Pressure sensitive tape (4)
End Panel/
Replace authorized unserviceable parts
Repair actions include sheet metal straightening, smoothing and grinding,
applying a primer coating, and applying a final protective coat of
polyurethane coating. See TM 43-0139.
Cut five strips of pressure sensitive tape (4), each 28.25 inches long, from
bulk pressure sensitive tape.
REASSEMBLY
End Panel/
Using camloc fastener tool and camloc fastener pliers, install turnlock
Retaining ring (1)
fastener eyelets (3), turnlock fastener stud assemblies (2), and retaining
Turnlock fastener stud
rings (1), as necessary.
assemblies (2)
Turnlock fastener
Apply pressure sensitive tape (4) to inside of the end panel
eyelets (3)
Pressure sensitive tape (4)


Privacy Statement