CONTROL BOX ASSEMBLY.

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  174    175    176    177    178  179  180    181    182    183    184  
img
Side Panel/
Retaining rings (1)
Using proper tools, remove retaining rings (1), turnlock fastener stud
Turnlock fastener stud
assemblies (2), and turnlock fastener eyelets (3), as necessary.
assemblies (2)
Turnlock fastener
Scrape off and discard old pressure sensitive tape (4) from side panel.
eyelets (3)
Pressure sensitive tape (4)
Replace authorized unserviceable parts.
Side Panel/
Repair actions include sheet metal straightening, smoothing and grinding,
applying a primer coating, and applying a final protective coat of
polyurethane coating. See TM 43-0139.
Cut six strips of pressure sensitive tape (4), each 21 inches long, from
bulk pressure sensitive tape.
Side Panel/
Retaining ring (1)
Using camloc fastener tool and camloc fastener pliers, install turnlock
Turnlock fastener stud
fastener eyelets (1), turnlock fastener stud assemblies (2), and retaining
assemblies (2)
rings (1), as necessary.
Turnlock fastener
Apply pressure sensitive tape (4) to inside of side panel.
eyelets (3)
Pressure sensitive tape (4)