TM 3-4230-209-30&P
2-146
2- 32. LIQUID STORAGE TANK (CONT).
REMARKS
ACTION
LOCATION/lTEM
Replace authorized unserviceable parts.
Liquid Storage Tank/
Scrape old gasket (1) off of the bottom
Gasket (1)
of the flange and discard. Fabricate a
gasket (1) to bottom of the flange using
adhesive.
Liquid Storage Tank/
Wrap all external threads with antiseiz-
Pipe nipple (1)
ing tape or coat with sealing compound
Body (2)
before reassembly.
Pipe elbow (3)
Screw pipe nipple (1) into the body (2)
and pipe elbow (3) onto the end of pipe
nipple (1). Tighten and position pipe nip-
ple (1) and pipe elbow (3). The opening
in pipe elbow (3) must be pointed so it
alines with the hole in the flange of the
body (2).