LIQUID STORAGE TANK. - Continued
LIQUID FUEL WATER HEATER AND CABINET TOP COVER.

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  148    149    150    151    152  153  154    155    156    157    158  
img
Screw one pipe locknut (4) onto the longest threaded end
Pipe locknuts (4)
Metallic pipe (5)
of metallic pipe (5). Insert metallic pipe (5) through the
Body flange (6)
body flange (6) on the body (2). Screw the other end of
metallic pipe (5) into pipe elbow (3). Screw second pipe
locknut (4) onto metallic pipe (5), protruding above the
body flange (6), and screw two pipe locknuts (4) fingertight
against body flange (6). Tighten metallic pipe (5) and two
pipe locknuts (4).
Screw pipe elbow (7) onto end of metallic pipe (5) and
Pipe elbow (7)
tighten.
Quick disconnect nect
Screw quick disconnect coupling half (8) onto pipe
elbow (7) and tighten.
coupling half (8)
Coat underside of body flange (6) with adhesive. Position
Gasket (9)
new gasket (9) form around body flange (6). Trim any
excess gasket (9) to fit.
TM 3-4230-209-30&P
2-147