PUMP UNIT ASSEMBLY. - Continued
PUMP UNIT ASSEMBLY. - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  40    41    42    43    44  45  46    47    48    49    50  
img
Pump Unit Assembly/
Wire (16)
Connect wire (16) from START-RUN-STOP SWITCH to the oil pressure
Oil pressure switch (17)
switch (17) on the engine. Reconnect engine disconnect cable (18) (con-
Engine disconnect
netted to TB1 at one end) to the rear of the engine.
cable (18)
Hexagon head cap
Remove hexagon head cap screw with resistor lead (19) from alternator
screw (19)
assembly (21). Position cable (20) on hexagon head cap screw (19) and
Cable (20)
reinstall hexagon head cap screw in alternator assembly (21). Route the
Alternator assembly (21)
cable (20) over and up to the bottom of alternator junction box (22) and
Alternator junction box (22)
connect.