PUMP UNIT ASSEMBLY. - Continued
PUMP UNIT ASSEMBLY. - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  35    36    37    38    39  40  41    42    43    44    45  
img
TM 3-4230-209-30&P
2-34
2-14. PUMP UNIT ASSEMBLY (CONT).
ACTION
LOCATION/lTEM
Loosen setscrew (13) and remove handwheel (14) from VALVE NO. 1
Setscrew (13)
MANIFOLD stem.
Handwheel (14)
NOTE
Handwheel maybe held on with a drive pin.
Remove one hexagon head self-locking nut (15), machine screw (16), and
Hexagon head self-locking
electrical connector cover (17).
nut (15)
Machine screw (16)
Electrical connector
cover (17)
Remove hexagon head cap screw (18) and flat washer (19). Slide loop
Hexagon head cap
clamp (20) from cable (21).
screw (18)
Flat washer (19)
Unscrew cable (21) electrical connector from the bottom of the alternator
Loop clamp (20)
junction box. Remove hexagon head cap screw (22) from the alternator
Cable (21)
assembly (23) and remove cable (21). Reinstall hexagon head cap
Hexagon head cap
screw (22) with resistor lead into alternator assembly (23).
screw (22)
Alternator assembly (23)