2-28
TM 3-4230-209-30&P
2-11. ACCESS COVER (CONT).
LOCATION/lTEM
ACTION
REMARKS
Access Cover/
Gaskets
Replace authorized unserviceable parts. When gaskets are loose but not
brittle or damaged, rebond to cover panel with adhesive. Fabricate gas-
kets (fig D-1 2) as required. Fabricate gaskets (fig D-10) as required.
Cover panel
Repair cover paneI by straightening dents, removing rust, and repainting
lettering with black polyurethane coating and small paint brush. Use
green polyurethane coating to paint the panel. Refer to TM 43-0139.
Repaint REMOVE BEFORE OPERATING in 1 1/2 inch high lettering with
black polyurethane coating.
Access Cover/
Gaskets (1)
Bond gaskets (1) to back side of cover panel (2) with adhesive. Cut holes
Cover panel (2)
in gaskets (1) at assembly to fit.
Gaskets (3)
Bond gaskets (3) to back side of cover panel (2) with adhesive. Cut holes
in gaskets (3) at assembly to fit.
Turnlock stud
Use camloc fastener tool and camloc fastener pliers to replace turnlock
assemblies (4)
stud assemblies (4), turnlock fastener eyelets (5), and retaining rings (6).
Turnlock fastener
eyelets (5)
Retaining rings (6)