TM 10-8415-208-12
3-10. REBREATHER SYSTEM MAINTENANCE INSTRUCTIONS. (CONT)
(4)
Connect flow restrictor (6) to air line connection (7).
(5)
Place clamp (4) around pressure gauge line (5).
(6)
Install washer (3), lock nut (2) and pan head screw (1).
(7)
Perform steps b. (16) through b. (20) and b. (24), paragraph 3-10. 3. 4, to install the center section.
(8)
Perform the Plumbing Leak Test and Breathing System Leak Test. Refer to paragraphs 3-10. 4. 1 and 3-10. 4.
2.
(9)
Install the cover.
3-10. 3. 8 Removing/Installing Harness/Carrying Strap.
a.
Removing.
(1)
Lay the rebreather system on a flat surface.
(2)
Release the latches on the bottom of the rebreather system and remove the cover.
(3)
Remove the oxygen bottle by performing steps a. (3) through a. (5), paragraph 3-10. 3. 1.