TM 10-8415-208-12
(22)
Position absorbent canister (14) and push it down into center section (15).
(23)
Position center section cover (13) on center section (15) and slide the four snap latches (12) closed.
(24)
Install coolant canister (5) and connect coolant canister hose (4) and inhalation hose (3).
(25)
Install oxygen bottle (2) performing steps b. (1) through b. (6), paragraph 3-10. 3. 1.
(26)
Perform the Plumbing Leak Test, Breathing System Leak Test and the Oxygen Constant Flow Rate Test. Refer
to paragraphs 3-10. 4. 1 through 3-10. 4. 3.
(27)
Install cover (1).
3-10.3.5 Removing/Installing Stat-Seal.
a. Removing.
NOTE
Replace the stat-seal when damage is found or suspected.
(1)
Place the rebreather system on a flat surface.
(2)
Release the latches on the bottom of the rebreather system and remove the top cover.
(3)
Remove the oxygen bottle performing steps a.(3) through a.(5), paragraph 3-10.3.1.
3-95