TM 10-8415-208-12
(4)
Perform steps a. (4) through a. (8) and a. (12) and a. (13), paragraph 3-10. 3. 4, to remove the center
section.
NOTE
Use care not to damage any air line tubing when removing the harness.
(5)
Carefully pull harness (1) ends out of lower housing (2) as far as possible for access.
(6)
Remove caps (3) and (4) from retaining pins (5) and (6).
(7)
Remove retaining pins (5) and (6) from harness (1).
(8)
Carefully pull harness (1) through the openings in lower housing (2).
(9)
Remove caps (7) from retaining pins (8).
(10)
Remove retaining pins (8) from carrying strap (9).
(11)
Pull carrying strap (9) through the openings in lower housing (2).
b. Installing.
(1)
Work carrying strap (9) ends through the openings in lower housing (2).
(2)
Push retaining pins (8) through the ends of carrying strap (9).
(3)
Snap caps (7) onto retaining pins (8).
(4)
Work new harness (1) ends through the openings in lower housing (2).
(5)
Pull new harness (1) ends through the openings as far as possible for access.
(6)
Push retaining pins (5) and (6) through the ends of new harness (1).
(7)
Snap caps (3) and (4) onto retaining pins (5) and (6).
(8)
Carefully work new harness (1) ends down into lower housing (2) so retaining pins (5) and (6) lay flat against
lower housing (2).
(9)
Perform steps b. (16) through b. (20) and b. (24), paragraph 3-10. 3. 4, to install the center section.
(10)
Perform steps b. (1) through b. (6), paragraph 3-10. 3. 1, to install the oxygen bottle.
3-101