TM 10-8415-208-123-8. ICEVESTMAINTENANCEINSTRUCTIONS. (CONT)(1)Disconnect battery connector (1) from pump connector (2). Unhook hook and pile fastener tape strap (3)and remove battery (4).b.Installing.(1)Position new battery (4) and secure it in place using hook and pile fastener tape strap (3).(2)Connect battery connector (1) to pump connector (2).3-8.3Service.a.Disconnect battery connector (1) from pump connector. Unhook the hook and pile fastener tape strap andremove battery (2).b.Connect battery (2) connector (1) to battery charger (3) connector (4).c.Plug battery charger (3) into a standard electrical outlet.NOTEThe battery requires 10-16 hours to fully charge.3-36