TM 10-5410-228-24
3.10.2 TALP Airlock Door Assembly Repair Continued.
(1)
Secure hose guard (65) to inside door frame assembly (38) with two rivets (64) (Item 76, Appx
Adhesives and cleaners are flammable and give off harmful vapors. Use adhesive and cleaner
sparingly and only in well ventilated area. Avoid prolonged breathing of vapors. Keep away
from heat, sparks, open flames. Wear gloves when handling adhesive and cleaner.
NOTE
Apply new gasket to clean, dry surface only. Clean adhesive residue from door weldment
with rag dampened with alcohol. Allow door weldment to dry completely before applying new
gasket.
(2)
Remove protective tape backing from new gasket (63) and cut to fit door weldment (56); secure
gasket (63) around inside edge of door weldment (56) with adhesive.
NOTE
Two screws and two lockwashers are supplied with latch.
(3)
Secure latch (60) to door weldment (56) with two screws (61) and two lockwashers (62).
NOTE
Two nuts, two lockwashers and latch cam are supplied with latch.
(4)
Install two nuts (57), two lockwashers (58) and latch cam (59) onto threaded post of latch (60).
(5)
Secure door hinge (52) to door weldment (56) with four screws (52), four flat washers (53), and
four self-locking nuts (55) (Item 44, Appx E).
(6)
Secure door hinge (52) to inside door frame assembly (38) with five screws (49), five flat washers
(50), and five self-locking nuts (51) (Item 44, Appx E).
(7)
Move two nuts (57) as necessary to adjust position of latch cam (59) on latch (60) to ensure latch
(60) holds door weldment (56) securely in place in inside door frame assembly (38) when door
weldment (56) is closed.
(8)
Secure two lockplate assemblies (48) to inside door frame assembly (38) with two hand knobs
(45), two flat washers (46), two Teflon washers (47), two flat washers (44), and two new cotter
pins (43) (Item 68, Appx E). Leave room for two TALP rail assemblies to slide in place between
two lockplate assemblies (48) and inside door frame assembly (38).
(9)
Secure clamp latch (35) to retaining clamp (36) with six screws (42) and six new self-locking
(10) Position TALP tunnel fabric (37) over inside door frame assembly (38), ensuring four grommets
(39) engage four pins (40).
The slots on retaining clamp must align with pins or damage to pins may occur.
(11) Position retaining clamp (36) over TALP tunnel fabric (37) and inside door frame assembly (38),
with slots on retaining clamp (36) engaged on pins (40), and close clamp latch (35).
c.
See para 3.10.1 for repair of holes, cuts, or tears in fabric of inside TALP door.
3-156