TM 10-5410-228-24
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools/Test Equipment:
Equipment Conditions:
Shop Equipment, Automotive Maintenance and
Power shut off. Power panel and rear control panel
tagged.
ECV parking brake set.
ECU covers and doors opened or removed, as
Plenum removed (see TM 10-5410-228-10).
ECU work platform installed (reference
TM 10-5410-228-10).
Materials/Parts:
References:
TM 10-5410-228-10
Materials/Parts: (Cont.)
The hydraulic system is pressurized. To prevent injury to personnel, gloves and eye
protection must be worn when working on hydraulic system.
NOTE
A small amount of hydraulic fluid will be released when removing tubes. Collect fluid in cup
or small container and clean any spillage with rags.
Remove/disassemble only to the extent necessary to remove or replace defective
assemblies/components. Use standard maintenance shop practices/procedures.
(1)
Disconnect tube assembly (1) from elbow (2) on hydraulic motor (3). Remove and discard O-ring
(4) from elbow (2).
(2)
Disconnect tube assembly (5) from elbow (6) on hydraulic motor (3). Remove and discard O-ring
(7) from elbow (6).
(3)
Disconnect tube assembly (8) from connector (9) on adapter (10). Remove and discard O-ring
(11) from connector (9).