TM 10-5410-228-24
(2)
Apply antiseize compound to shaft of hydraulic motor (14).
(3)
Slide condenser fan motor shaft (3) onto shaft of hydraulic motor (14). Tighten setscrew (22).
(4)
Apply sealant to two setscrews (22) on condenser fan motor shaft (3).
(5)
Loosely secure fan support bracket (27) with hydraulic motor (14) attached to ECU enclosure
(28) with four screws (23), eight flat washers (24), four new lockwashers (25) (Item 20, Appx E)
and four nuts (26).
(6)
(7)
Adjust support bracket (27) so that condenser fan (2) will be centered in ECU enclosure (28).
Tighten four screws (23) and four nuts (26).
(8)
Check connector (8) sealing surfaces for damage or material build up. If required, replace
connector (8) or clean any material build up with clean, lint-free cloth.
(9)
Coat male threads of connector (8) with hydraulic sealant.
(10) Remove plug from port on hydraulic motor (14). Install connector (8) on hydraulic motor (14),
finger tight.
(11) Wrench tighten connector (8) two to three TFFT.
(12) Lubricate O-ring (21) (Item 62, Appx E) with a light coating of hydraulic fluid and install on
connector (8). Ensure that O-ring (21) is seated and retained properly.
(13) Check tee (7) sealing surfaces for damage or material build up. If required, replace tee (7) or
clean any material build up with clean, lint-free cloth.
(14) Install tee (7) on connector (8), finger tight.
(15) Check elbow (17) sealing surfaces for damage or material build up. If required, replace elbow
(17) or clean any material build up with clean, lint-free cloth.
(16) Lubricate O-ring (20) (Item 51, Appx E) with a light coating of hydraulic fluid and install on
elbow (17). Ensure O-ring (20) is seated and retained properly.
(17) Coat male threads of elbow (17) with hydraulic fluid.
(18) Remove plug from port on hydraulic motor (14). Install elbow (17) on hydraulic motor (14),
finger tight.
(19) Check elbow (13) sealing surfaces for damage or material build up. If required, replace elbow
(13) or clean any material build up with clean, lint-free cloth.
(20) Lubricate O-ring (19) (Item 51, Appx E) with a light coating of hydraulic fluid and install new
O-ring (19) on elbow (13). Ensure O-ring (19) is seated and retained properly.
(21) Coat male threads of elbow (13) with hydraulic fluid.
(22) Remove plug from port on hydraulic motor (14). Install elbow (13) on hydraulic motor (14),
finger tight.
(23) Lubricate two O-rings (10) (Item 62, Appx E) with a light coating of hydraulic fluid and install
on tee (7). Ensure O-rings (10) is seated and retained properly.
(24) Coat male threads of reducer (6) and install in tee (7) finger tight.
(25) Lubricate O-ring (9) (Item 67, Appx E) with a light coating of hydraulic fluid and install on
reducer (6). Ensure O-ring(9) are seated and retained properly.
(26) Remove two plugs from two tube assemblies (5 and 11). Check two tube assemblies (5 and 11)
sealing surfaces for damage or material build up. Clean any material build up with clean, lint-
free cloth. If required, replace tube assemblies (5 and 11) per para 3.9.11.
(27) Coat male threads of tee (7) and reducer (6) with hydraulic fluid and install two tube assemblies
(5 and 11) finger tight. Adjust position of two tube assemblies (5 and 11) and tee (7) as required.
3-53