TM 10-5410-228-24
(1) Remove end cap (1) on female power cord (2) from luminaire (3).
(2) Remove lampholder (4) by depressing retainer connector (5).
(3) Cut female power cord (2) wires from lampholder (4) and pull power cord (2) out of end cap (1).
(1) Insert loose wire end of new female power cord (2) through end cap (1) so that approximately
three inches of cord are inside end cap (1).
(2) Remove outer insulation from power cord (2) on inside of end cap (1), and approximately 1/2
inch from individual wires.
(3) Solder power cord (2) wires to lampholder (4) wires.
(4) Install lampholder (4).
(5) Install end cap (1) onto luminaire (3).
(1)
Remove fuse cap (1) and fuse (2).
(2)
Remove molded male and female end caps (3,4) from luminaire (5).
(3)
Disconnect lampholder (6) by depressing retainer connector (7).
(4)
(5)
Remove splices (11) and disconnect black (12) and white (13) wires of male power cord (14).
(6)
Disconnect male power cord ground wire (15) from ground post (16).
(7)
Pull male power cord (14) out of molded end cap (3) and bushing (17).
(1)
Push male power cord (14) through male molded end cap (3) and bushing (17).
(2)
Connect black (12) and white (13) wires of male power cord (14) and reinstall splices (11).
(3)
Connect male power cord ground wire (15) to ground post (16).