2.16.5 Pressure Gage Assembly Repair Continued.
(2)
Screw two female elbows (15) into back of two pressure gages (18). Ensure nipple end of female
elbows (15) are pointing down.
(3)
Install plastic tubing (13) on female elbow (15).
(4)
Install plastic tubing (12) on female elbow (15).
(5)
Secure two brackets (20) to the back of two pressure gages (18) with four nuts (19).
(6)
Screw two female elbows (17) to the back of two pressure gages (18). Ensure nipple end of
female elbows (17) are pointing inward.
(7)
Install two plastic tubings (16) on two female elbows (17).
(8)
Install two plastic tubings (16) on ends of tee union (14).
(9)
Install plastic tubing (11) on tee union (14).
NOTE
Heat plastic tubing to ensure tubing fits over 3 barbs on quick disconnects.
Use heat gun to seal heat-shrink tubing.
(10)
Install quick disconnect (3) on plastic tubing (13). Seal plastic tube (13) on quick disconnect (3)
by installing a 1.5 inch piece of electrical insulation sleeving over tube (13) and quick disconnect
(3).
(11)
Install quick disconnect (1) on plastic tubing (12). Seal plastic tube (12) on quick disconnect (1)
by installing a 1.5 inch piece of electrical insulation sleeving over tube (12) and quick disconnect
(1).
(12)
Install quick disconnect (2) on plastic tubing (11). Seal plastic tube (11) on quick disconnect (2)
by installing a 1.5 inch piece of electrical insulation sleeving over tube (11) and quick disconnect
(2).
(13)
Install two straps (4) onto mounting bracket (10).
(14) Secure mounting bracket (10) to mounting plate (5) with two screws (7), two flat washers (8) and
two nuts (9).
(1)
Pull two straps (4) through two loops (6) on ABS end wall and two slots on mounting plate (5).
(2)
Fold over ends of two straps (4), engaging fastener hook and fastener loop.
(3)
Connect ambulatory airlock quick disconnects (1) together.
(4)
Connect outside ambient air quick disconnects (2) together.
(5)
Connect TALP airlock quick disconnects (3) together.