TM 10-5410-228-10
3.9
OPERATOR TROUBLESHOOTING - Continued.
Table 3-9. Circuit Breaker and Switch Configuration for Static Mode, External Power, VENT,
NBC - Continued
Item Name
Configuration
Circuit Breaker (located on LMS exterior Power
Panel)
Switch ON
Converter DC OUTPUT Switch
ESS MODE
VENT
MISSION PROFILE
STATIC
POWER MODE
EXT
RIB FAN
NBC FAN
EXTERNAL HYDRAULIC PUMP
Section III. OPERATOR MAINTENANCE PROCEDURES
3.10 GENERAL.
This section provides information on operator maintenance procedures. Remove/disassemble only to the
extent necessary to remove or replace defective assemblies/components. Use standard maintenance shop
practices/procedures.
3.11 LIGHTWEIGHT MULTIPURPOSE SHELTER (LMS).
3.11.1 Forward Light Box Assembly Lamp Replacement.
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Tools/Test Equipment:
Equipment Conditions:
Screwdriver
System power OFF. ECV parking brake set.
LTG/INTERCOM circuit breaker OFF and tagged.
Materials/Parts:
Two Halogen Lamps (57431) 2420 or equivalent
Incandescent Lamp (08803) 4593 or equivalent
a. Removal (Refer to figure 3-1)
(1)
Turn lens and reflector (1) counterclockwise on task lamp (2) and remove lens and reflector (1).
Remove O-ring (3). Do not discard O-ring.
(2)
Pull halogen lamp (4) from task lamp (2).
(3)
Pull lamp (5) and lamp retainer (6) from forward light box assembly (7).
(4)
Tag wires and remove two screws (8) securing wires to lamp (5).
(5)
Pull lamp (5) from lamp retainer (6).
3-46