T.O. 33B-1-11-29b. Verify that black light intensities are within acceptable limits.1.5.2.13.6Postcleaning.a. Verify that removal of developer residues is accomplished in a satisfactory manner.b. Verify that removal of penetrant residues is accomplished in a satisfactory manner.1.5.3ControlOfNewMaterials.1.5.3.1NewlyReceivedMaterials.Penetrant system materials (penetrants, emulsifiers and removers, and wet and dry developers) are compounded orformulated in batches or lots. It is possible for one batch or lot among several to have characteristics that do not meetthe specification requirements. Therefore, each batch or lot of penetrant, emulsifier and remover, and wet and drydevelopers SHALL be tested on receipt, prior to in-service use. Quality conformance tests for newly received materialsare described in paragraph 1.5.3.4. The batch or lot of material can be identified by batch or lot number on eachcontainer.1.5.3.2Procurementprovisions.Penetrant system material procurement SHALL meet the following requirements:a. Materials SHALL comply with the current version of ASM 2644.b. Except for solvent removers, bidders SHALL have material listed (or approved for listing) on the mostcurrent revision of QPL-25135.c. Contract and special purchase orders for procurement of materials SHALL require a certified test reportand a quality conformance sample submitted in accordance with the latest revision of ASM 2644.d. Materials listed on QPL-25135 and those centrally procured using generic national stock numbers(NSNs) need not comply with paragraph 1.5.3.4c.1.5.3.3SamplingOfNewlyReceivedMaterials.1.5.3.3.1General.Two samples are required from each batch or lot of penetrant, emulsifier or remover, and/or wet and dry developerwhen received. If the supplier has submitted a quality conformance sample, (see paragraph 1.5.3.3.2.1), only oneadditional sample will be required. Either one or two samples SHALL be taken from each batch or lot of penetrant,emulsifier and remover, and wet and dry developer, when received and prior to use. One sample, either from thesupplier or locally taken, will be used to verify the Quality Conformance as described in paragraph 1.5.3.4. The secondsample, which may be larger than the first, will be retained by the using activities as a reference standard for periodicprocess performance tests.1.5.3.3.2SampleSizes.1.5.3.3.2.1 QualityConformanceSamples.For all items except developer solids, a sample of not less than 1 quart or more than 1 gallon SHALL be taken fromeach batch or lot of each material. For each batch or lot of wet developers in the dry condition, a 2-pound sampleSHALL be selected, and from each batch or lot of dry developer solids a 1 pound sample SHALL be selected.1.5.3.3.2.2 ProcessControlReferenceSample.These samples will be used as reference or master standards in comparing the performance of the in-use material. Thesample size will depend upon the workload which determines the frequency of process control testing. A suggestedsample size for high volume workload systems is 1 to 2 gallons (for all items except developer solids) from each batch
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business