T.O. 33B-1-11-30or lot of materials. The suggested quantity of wet developers in the dry condition is 2 pounds with a 2 pound sample ofdry developer solid. A minimum sample size for penetrant systems that have an occasional workload (see paragraph1.5.1.5) requiring fewer process control checks, SHALL be as stated in paragraph 1.5.3.3.2.2. Each depot and baseSHALL be responsible for determining the sample size required for its workload. The reference sample SHALL belarge enough to permit the required process control checks during the life of the material and still have a quantity ofreference sample to run a comparison check against the new materials when the old solution is finally discarded.1.5.3.3.3 SampleHandlingandStorage.Care must be exercised in obtaining, handling, and storage of the reference samples to prevent contamination ordegradation. The containers SHALL be metal or glass since many plastics are attacked by the penetrant oils andsolvents. The same restriction applies to the seals or washers in the container lids. The sample containers SHALL beclean, dry, and have tight fitting lids or covers. The devices used for obtaining the sample must not contain traces ofother batch or lot materials. The samples SHALL be stored in a cool area and not exposed to sunlight, black lights orhigh intensity white lights.1.5.3.4 QualityConformanceTesting.The following procedures SHALL be used to verify the quality conformance of newly received materials:a. For materials that are not centrally procured using a generic stock number, the NDI laboratorysupervisor SHALL review the test report and SHALL accomplish a system performance test comparingthe newly received material against the process control reference sample (paragraph 1.5.3.3.2.2) thatwas used to check the in-use material (paragraph 1.5.5). Compare old penetrant to replacement.b. The newly received material may be accepted when both the system performance test and the test reportare positive. (Test reports and quality conformance tests are not required for materials centrallyprocured using generic national stock numbers).c. If a test report is required but not received with the material, the NDI supervisor SHALL check withbase procurement to see if a test report was received. If a test report is not available, a test sample maybe sent per paragraph 1.5.3.4d or tested per paragraph 1.5.3.4e. Test reports are not required forgeneric National Stock Numbers (NSNs).d. If the system performance test results are not conclusive or the test report (if required) is not available, asample selected in accordance with paragraph 1.5.3.3.2.1 SHALL be submitted to: AFRL/MLSA Bldg652, 2179 Twelfth Street Ste. 1, Wright-Patterson Air Force Base OH 45433-7718. AFRL/MLSA willprovide the submitting field laboratory a test report with the results of the quality conformance tests andrecommend acceptance or rejection of the batch or lot of materials.e. Depots Only: Depots with appropriate analytical equipment and competent technicians to perform therequired tests may test the following properties for compliance with ASM 2644 in accordance withapplicable procedures referenced in the specification: flash point of penetrants and lipophilicemulsifiers, viscosity of penetrants and emulsifiers, fluorescent brightness of penetrants, thermalstability of penetrants, water tolerance of water washable penetrants and lipophilic emulsifiers,redispersibility of nonaqueous wet and aqueous suspended developers, developer fluorescence, penetrantremovability, and water content of hydrophilic remover concentrate.
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business