TM 5-6635-386-12&P(6) The only vacuum cleaners that shall be usedare those with absolute filters which have been tested forfiltration efficiency. Testing filtration efficiency ismandatory each time the filter is replaced, and each timeits contents are emptied.c. Radioactive waste shall be disposed of in amanner to comply with AR 385-11.MAINTENANCE4-35.TESTER MAINTENANCEa. Only limited and specific maintenance isauthorized for the tester. Personnel authorized toperform maintenance are the operator and the LRPO.Neither the operator nor the LRPO are authorized torepair the tester (see Para 4-37).b. Operator performed maintenance is limited tothe following:(1) Cleaning the testers external surfaces andshutter assembly.(2) Changing fuses.(3) Changing batteries.(4) Charging batteries.(5) Perform leak test in absence of qualifiedLRPO or ALRPO.c. LRPO performed maintenance is limited to thefollowing:(1) Perform the leak test.(2) When required, the LRPO shall performmaintenance that is normally accomplished by theoperator.4-36. TESTER REPAIR AND DISPOSALa. A tester requiring repair or disposal must bereturned to a designated manufacturer’s repair facility.b. Do not use the tester when it fails to operate inaccordance with preoperation checks described in theoperator’s manual.c. Contact the NICP for disposition instructions.See Para 4-38a.d. Contact the Commander, TACOM, ATTN:AMSTA-MVC if all operating modes of the tester are notfunctioning correctly. Users are requested to submit aQuality Deficiency Report (QDR) on Standard Form 368in accordance with DA Pam 738-750 to the address inPara 4-39b.ASSISTANCE4-37. SAFETY.Copies of surveys, leak test results,incident reports, other applicable data and reports, DAForm 3252-R, and questions pertaining to the tester andpersonnel safety shall be directed to:CommanderUS Army Tank-Automotive CommandATTN: AMSTA-CZ (Safety Office)Warren, MI 48397-5000Telephone:Autovon:786-6121 or 61 94Commercial: (313) 574-6121 or 6194After office hours:Autovon: 786-5511Commercial: (313) 574-55114-38. TESTER REQUISITION, AND DISPOSITION.Questions or requests pertaining to tester requisition,and disposition shall be directed to:a. CommanderUS Army Tank-Automotive CommandATTN: AMSTA-FHV (NICP)Warren, MI 48397-5000Telephone: Autovon: 786-5827 or 7787Commercial: (313) 574-5827 or 7787Questions pertaining to tester maintenance shall bedirected to:b. CommanderUS Army Tank-Automotive CommandATTN: AMSTA-MVC (Maintenance)Warren, MI 48397-5000Telephone: Autovon: 786-8298/7358Commercial: (313) 574-8298/73584-13
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business