TM 5-6635-386-12&P(1) Proper Shipping Name: Radioactive Material,Special Form, N.O.S.(2) Hazard Class: Radioactive Material.(3) Identification Number: UN 2974.(4) Total Quantity: 1 Box.(5) Name of each Radionuclide: Americium241,Cesium-137.(6) Form: Special Form.(7) Activity: 60 millicuries total, 10 millicuriesCesium-137, 50 millicuries Americium-241 (8) LabelRequired: Radioactive Yellow-l.(9) Transport Index: Use value listed on Yellow IIlabel on box.(10) The following accessories are to be included withthe testers when transporting them for repair/overhaul orto a new location:DESCRIPTIONFSCMPART NO.NSNCast Aluminum Guideplate55492B 2000506635-01-043-7970Computer Tabulations AC Charger55492NB-150-86635-01-043-7972DC Charger (Battery Clips)55492A 4012346635-01-043-7973Sign Set55492W10069905-01-115-8157Phillips Screwdriver79061P285120-00-542-3438Fiberglass Case55492A 401228No NSNPadlock w/2 Keys96906MS 35647-45340-00-582-2741Standard Drill Pin55492A2001286635-01-043-7971Clipboard Assembly55492B 1010137520-01-115-8066Standard Block Assembly55492B 401124No NSNWrench, Allen Hex, 5/328006419407175120-00-198-5392Battery, NICAD, 8 ea1920941B004AA71WTABS6140-00-497-0490(Size D-4 Ampere hour 160F)*Some testers were issued with a hammer. If applicable, the hammer should also be included. TM 5-6635-386-12&P shallalways stay with the tester even during shipment.(11) Handle must be locked in a safe positionand the batteries removed before tester is shipped.(12) The key for the padlock is to be tagged withthe tester serial number and sent by registered mail tothe receiving/repair facility. The key to the probe handleshall be stored inside the case.c. Additional information is required asappropriate depending on the mode of transportationused. Do not forget to include the following shippingcertification on the shipping papers:This is to certify that the above named materialsare properly classified, described, packaged, markedand labeled and are in proper condition for transportationaccording to the applicable regulations of theDepartment of Transportation.d. The orange tester case meets therequirements of specification 7A for type A packaging.Type A packaging is required for the tester since theradionuclides are in special form and the amount ofactivity of the two radioactive sources is below themaximum permitted for type A packaging (Al). However,to protect from damage during shipment, the tester andcase should be placed in a wooden crate. The outside ofthe crate must be labelled and marked in accordancewith Title 10 CFR Parts 172.310, 172.403 and 438. Acomplete DD Form 1348-1 (DOD Sirtgle Line ItemRelease/Receipt Document) should accompany theshipment to the manufacturer.e. The Transport Index (TI) must be marked onthe Dot Radiation label on the tester package, and on theshipping paper. The TI is a number expressing themaximum radiationlevel in millirem per5-3
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business