TM 5-6635-386-12&P
(1) Proper Shipping Name: Radioactive Material,
Special Form, N.O.S.
(2) Hazard Class: Radioactive Material.
(3) Identification Number: UN 2974.
(4) Total Quantity: 1 Box.
(5) Name of each Radionuclide: Americium241,
Cesium-137.
(6) Form: Special Form.
(7) Activity: 60 millicuries total, 10 millicuries
Cesium-137, 50 millicuries Americium-241 (8) Label
Required: Radioactive Yellow-l.
(9) Transport Index: Use value listed on Yellow II
label on box.
(10) The following accessories are to be included with
the testers when transporting them for repair/overhaul or
to a new location:
DESCRIPTION
FSCM
PART NO.
NSN
Cast Aluminum Guideplate
55492
B 200050
6635-01-043-7970
Computer Tabulations AC Charger
55492
NB-150-8
6635-01-043-7972
DC Charger (Battery Clips)
55492
A 401234
6635-01-043-7973
Sign Set
55492
W1006
9905-01-115-8157
Phillips Screwdriver
79061
P28
5120-00-542-3438
Fiberglass Case
55492
A 401228
No NSN
Padlock w/2 Keys
96906
MS 35647-4
5340-00-582-2741
Standard Drill Pin
55492
A200128
6635-01-043-7971
Clipboard Assembly
55492
B 101013
7520-01-115-8066
Standard Block Assembly
55492
B 401124
No NSN
Wrench, Allen Hex, 5/32
80064
1940717
5120-00-198-5392
Battery, NICAD, 8 ea
19209
41B004AA71WTABS
6140-00-497-0490
(Size D-4 Ampere hour 160F)
*Some testers were issued with a hammer. If applicable, the hammer should also be included. TM 5-6635-386-12&P shall
always stay with the tester even during shipment.
(11) Handle must be locked in a safe position
and the batteries removed before tester is shipped.
(12) The key for the padlock is to be tagged with
the tester serial number and sent by registered mail to
the receiving/repair facility. The key to the probe handle
shall be stored inside the case.
c.
Additional
information
is
required
as
appropriate depending on the mode of transportation
used. Do not forget to include the following shipping
certification on the shipping papers:
This is to certify that the above named materials
are properly classified, described, packaged, marked
and labeled and are in proper condition for transportation
according
to
the
applicable
regulations
of
the
Department of Transportation.
d.
The
orange
tester
case
meets
the
requirements of specification 7A for type A packaging.
Type A packaging is required for the tester since the
radionuclides are in special form and the amount of
activity of the two radioactive sources is below the
maximum permitted for type A packaging (Al). However,
to protect from damage during shipment, the tester and
case should be placed in a wooden crate. The outside of
the crate must be labelled and marked in accordance
with Title 10 CFR Parts 172.310, 172.403 and 438. A
complete DD Form 1348-1 (DOD Sirtgle Line Item
Release/Receipt Document) should accompany the
shipment to the manufacturer.
e. The Transport Index (TI) must be marked on
the Dot Radiation label on the tester package, and on the
shipping paper. The TI is a number expressing the
maximum
radiation
level
in
millirem
per
5-3