TM 5-6635-386-12&PLRPO, and shall be recorded in microcuries.d. Wipe tests made by users in the U.S., PuertoRico, Panama and Korea shall be sent to: Chief, us ArmyIonizing Radiation Dosimetry Center, AMXTM-S-LR-DN,Lexington, KY 40511-5102.e. Wipe tests made by USAREUR units shall besent to: Radiac ACL, Pirmasens, 524th Maintenance(TMDE) Co., APO NY 09138-4628.f. Overseas users in other than USAREUR unitswill be notified of Army laboratories to which wipe testsshall be sent.g. Units that receive leak test kits every sixmonths are not required to send test results to TACOM.The test results are forwarded to TACOM by the U.S.Army Ionizing Radiation Dosimetry Center.h. Users who do not receive leak test kits everysix months, shall send test results to Commander,TACOM, ATTN: AMSTA-CZ. Test results shall includethe LRPO’s name, and a statement that the tester isbeing used only by trained personnel.(1) The LR PO shall ensure that test results arerecorded and submitted on DA Form 3252-R (PunchCard Transmission Worksheet Radioisotope Inventoryand Leak Test Report), as required by AR 385-11 andPara 4-9e.(2) When filling out the DA Form 3252-R, usethe last five digits of the tester serial number for blocks18-22.i. The LRPO shall immediately withdraw a testerfrom use when results of leak testing reveal thepresence of 0.005 or more microcuries. Immediatelythereafter, the LRPO shall notify the installation’s RPO,the RCO, and the Commander, TACOM. The telephoneshall be used to notify TACOM. A request for instructionsfrom TACOM shall also be made during the telephonecall. TACOM (AMSTA-CZ) telephone numbers are:(1) During office hours: DSN 7866121/6194,Commercial (313) 574-6121/6194.(2) After office hours: DSN 786-5511,Commercial (313) 574-5511.4-26. LEAK TEST PROCEDUREa. The tester contains two sealed sources. Bothof the sources must be tested for radiation leakage tocomply with AR 385-11. See Para 4-25.b. The following items are required to performingthe leak test:(1) Transparent plastic wrapping material.(2) Pressure sensitive transparent tape.(3) Cotton swab with wooden stem.(4) Detergent and water solution.(5) Aluminum or other metallic foil.(6) Radiac meter AN-PDR/27 or equivalent.4-27. LEAK TESTa. Place a sheet of clean plastic wrap on anuncontaminated surface near the tester.b. Make sure the testers handle is locked in the"SAFE" position, and that the shutter is closed. (See Fig.4-1).Figure 4-1. Model MC-1 Nuclear Method Density andSoil Tester4-8
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business