TM 5-6350-264-14&P-9NAVELEX EE 181-AA-OMI-100/E121 DZ-204T.O. 31S9-2FSS9-1-9u. To remove connector P1, loosen screwsand disconnect P1 from J2. Tag wires.Use a soldering iron of 50 wattsmaximum to unsolder wires.Remove connector P1.v. To install new connector P1, solderwires to connector. Connect to J1 andtighten screws.w. To remove fuse holder assembly, slideinner enclosure part way out of outerenclosure. Remove screws from switchbracket. Lower switch bracket to gainaccess to fuse holder assembly. Tagwires and use a soldering iron of 50watts maximum to unsolder wires.Remove hex nut and remove fuseholder assembly.x. To install new fuse holder assembly,position assembly in switch bracket andinstall hex nut. Solder wires. Positionswitch bracket on inner enclosure andinstall mounting screws. Slide innerenclosure into outer enclosure.y. To remove varistor, remove screws frombarrier strip cover and remove barrierstrip cover. Note varistor wireconnection on TB1. Loosen terminalscrews and remove varistor.z. To install new varistor, install insulationtubing on varistor wires. Connect wiresto TB1 and tighten terminal screws.Position barrier strip cover and installmounting screws.WARNINGOperation of this equipment presents anoise hazard to personnel in the area.The noise level exceeds the allowablelimits for unprotected personnel.Authorized protective equipment mustbe worn by all personnel in the workarea.aa. After replacing major components orassemblies, test the Audible Alarm forproper operation. Set Control UnitPOWER switch to ON. Set Control Unitmode switch to SECURE. Initiate anintrusion alarm. The alarm shouldsound after expiration of time-delayperiod. Set Control Unit mode switch toTEST/ RESET and then to ACCESS.The alarm should stop. Using the key,unlock and slowly open Audible Alarmouter enclosure door. The AudibleAlarm should sound when door isopened 1/8 to 1/4 inch. Place the doortamper switch in the maintenanceposition. Set the Control Unit modeswitch to TEST/RESET and then toACCESS. The alarm should stop.Short the outer enclosure to the innerenclosure. The Audible Alarm shouldsound. Remove the short. Set theControl Unit mode switch to TEST/RESET and then to ACCESS. Thealarm should stop. Using the key, closeand lock the Audible Alarm outerenclosure door. The Audible Alarmshould sound. Set the Control Unitmode switch to TEST/RESET and thento ACCESS. The alarm should stop.5-30
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business