TM 5-6350-264-14&P-10NAVELEX EE 181-AA-OMI-110/E121 C-9412T.O. 31S9-2FSS9-1-10Table 5-2. Troubleshooting Procedures - ContinuedTroubleProbable causeCorrective action1.(Cont)d.(Cont)f.If meter still indicates less than 1 vdc,turn off switch S1 on power supply. Re-move PC board A8. Lift board ejectoruntil PC board pops out of receptacle,then grasp board and pull straight out.g.Turn on switch S1 on power supply. De-press TRANSMITTER RESYNC switchS2. Wait about 5 minutes for system tostabilize. Turn mode switch to TEST/RESET and then to SECURE.h.Set multimeter to dc volts and connectpositive meter lead to J8-11, and nega-tive lead to chassis (ground). Ensurethat no alarms are activated.i.If meter indicates more than 10 vdc, re-place PC board A7.(1) To Remove PC board A7, turn offswitch S1 on top of power supply.Place thumb or finger under boardejector and lift up until board popsout of receptacle at back of statusprocessor. Then grasp PC boardand pull straight out.(2) To install new PC board A7, turnboard so plastic ejector is towardtop. Align board with guides attop and bottom of status processor.Slide board straight in until it con-tacts receptacle at back of proces-sor. Then press firmly on boarduntil it seats completely in recep-tacle.(3) Turn on switch S1 on power sup-ply. Depress TRANSMITTERRESYNC switch S2. Wait about5 minutes for system to stabilize.Turn mode switch to TEST/RESET and then to SECURE.5-21