TM 5-6350-264-14&P-10NAVELEX EE 181-AA-OMI-110/E121 C-9412T.O. 31S9-2FSS9-1-10Table 5-2. Troubleshooting Procedures - ContinuedTroubleProbable causeCorrective action1.(Cont)d.(Cont)j.If meter indicates less than 1 vdc at J8-11,remove PC board A10 and install PCboard A8.(1) To remove PC board A10, turn offswitch S1 on top of power supply.Place thumb or finger under boardejector and lift up until board popsout of receptacle at back of statusprocessor. Then grasp PC boardand pull straight out.(2) To install PC board A8, turn boardso plastic ejector is toward top.Align board with guides at top andbottom of status processor. Slideboard straight in until it contactsreceptacle at back of processor.Then press firmly on board untilit seats completely in receptacle.(3) Turn on switch S1 on power sup-ply. Depress TRANSMITTERRESYNC switch S2. Wait about5 minutes for system to stabilize.Turn mode switch to TEST/RE-SET and then to SECURE.k.Connect positive meter lead to J10-7,and negative lead to chassis (ground).l.If meter indicates more than 10 vdc, re-place PC board A8.(1) To remove PC board A8, turn offswitch S1 on top of power supply.Place thumb or finger under boardejector and lift up until boardpops out of receptacle at back ofstatus processor. Then grasp PCboard and pull straight out.(2) To install new PC board A8, turnboard so plastic ejector is towardtop. Align board with guides attop and bottom of status proces-sor. Slide board straight in until5-22