TM 5-3740-218-13&P
4-10.
PMCS TABLE
Table 4-1. Unit Level PMCS (Cont)
NOTE: Within designated interval, these checks are to be performed in the order listed.
M-Monthly
S-Semiannually
A-Annually
ITEM
NO.
INTERVAL
ITEM TO BE
INSPECTED
PROCEDURE
M
S
A
15
LV Boom and
Check boom assembly (both sides) for obvious
Nozzles
exterior damage such as nicks, dents, or cracks.
Replace as required (para 4-46).
Check plastic nozzles for cross threading, nozzle
ends for obstruction. Replace or clean nozzles
(para 4-47).
Ensure spraying disc and core seal are properly
installed in quickjet cap.
Ensure quickjet cap is screwed on securely to
nozzle body. Secure cap.
Check for missing or damaged quick-release pins.
Replace as required (para 4-46).
Check quick-release pin mount holes for elongation.
Replace boom as required (para 4-46).
16
ULV Boom and
Check boom assembly for external damage such as
Rotary Atomizers
nicks, dents, or cracks. Replace as required
(para 4-48).
Check rotary atomizers for freedom of rotation and
obstruction. Clean or replace as required
(para 4-50).
Check hydraulic fittings for Class III leaks and
hoses for damage. Repair leaks or replace hoses as
required (para 4-48).
Check attaching hardware such as clamps and pins
for damage and security. Replace as required
(para 4-48).
17
Hopper Assembly
Check left and right hopper assemblies for exterior
damage such as dents or cracks. Replace as
required (para 4-53).
Check capacitive light switch and harness for
proper installation, damage, and security. Replace
(para 4-54) or tighten as necessary.
Check hydraulic cylinders and fittings for Class III
leaks. Repair leaks at fittings or replace cylinder
(para 4-54).
Check chutes for foreign objects. Clean as required.