TM 5-3740-218-13&P(12) Remove nozzle, pressure gage, and test tee. Install nozzle back in boom.b. ULV System Boom Assembly Pressure Adjustment.WARNINGPersonnel handling solid or liquid pesticides shall use appropriate personal protectiveequipment consisting of respirators, coveralls, rubber gloves, goggles, etc., as requiredby type of pesticide used and in accordance with manufacturer's label directions. Avoiddirect contact with pesticide. Observe all warnings on label. Handle pesticide in well-ventilated area. Failure to do so could result in personal injury.NOTEAll initial tests should be performed with water only. All following tests for calibrationshould be performed with pesticide.(1) Remove fitting (1) from rotary atomizer nozzle (2) and install test tee (3), pressure gage (4), and fitting (1) asshown in figure 2-10.Figure 2-10. ULV Boom Pressure Adjustment2-28