TM 5-3740-218-13&P
Table 2-4. Operator Level PMCS (Cont)
NOTE: Within designated interval, these checks are to be performed in the order listed.
B-Before
D-During
A-After
B
D
A
Strainer
Check for cleanliness; clean with
Strainer plugged.
water or appropriate solvent.
Pump and
Check hydraulic couplings for
Fails to operate.
Crosstube
correct location and secureness of
Spray
hookup. Check operation with
System
hand control.
Control
Valve
Level
Check connections. Check for
Fails to operate.
Sensors
proper operation (indicator lights
when bucket is empty).
11
LV Booms
Check for proper assembly. Make
Cannot be secured.
and Struts
sure all quick-release pins are
secured.
Boom
Check for missing or compressed
Missing, or leaks
Kamlock
gaskets. Check for leaks.
exceed Class II.
Gaskets
Spray
Check for leaks using water.
Leaks exceed Class II,
Nozzles
Check for correct/uniform spray
or spray produces
pattern. If threads are stripped
excessively large
or body cracked, refer to unit
droplets.
maintenance.
12
ULV Boom
Check for secure attachment,
Not secured, or broken.
broken, or missing parts.
Quick-release pins should be fully
engaged.
Boom
Check for missing or compressed
Missing, or leaks
Kamlock
gaskets. Check for leaks.
exceed Class II.
Gaskets
Liquid
Check for leaks at all connections.
Leaks exceed Class II.
Pesticide
Lines
Nozzles
Check for leaks using water.
Leaks exceed Class II.
2-12
INTERVAL
ITEM
NO.
Item To Be
Inspected
EQUIPMENT IS NOT
READY/AVAILABLE IF:
Procedures