TM 5-3740-218-13&PTable 2-4. Operator Level PMCS (Cont)NOTE: Within designated interval, these checks are to be performed in the order listed.B-BeforeD-DuringA-AfterBDA•Sling HookCheck for tightness of hardwareEssential hardwareAssemblyinside and outside of bucket.missing.Check hook for ease of swivelaction; if swivel action is notsmooth, lubricate.•WiringCheck wiring harness for cut orInsulation or wiresHarnesstorn insulation, frayed or brokendamaged.wires. Check harness mountingclamps for security.•Sight GagesCheck sight gages for damageDamaged or missing.and security.7•LiftingInspect for frays and cuts orStrap frayed, cut, orStrapsigns of weakness.missing.8•HandCheck connections andDamaged, or notControlquick-release coupling for properoperating properly.Harnessfit and operation. Check safetySafety cable damagedcable for damage and security.or missing.9•PrimaryCheck for leaks. Check hydraulicLeaks exceed Class II.andlines for proper routing.SecondaryHydraulicManifolds•PressureCheck gage pressure (should readPressure notGage900-1200 psi); adjust if necessary.attainable.(PrimaryManifold)•PressureCheck gage pressure (should readPressure notGage300 psi in all modes); adjust ifattainable.(Secondarynecessary.Manifold)10••LiquidCheck all L-clamps for tightness.Leaks exceed Class II.SystemCheck for cracked or broken earsPump andon mounting plates. Check forCrosstubeleaks anywhere in system.Assembly2-11INTERVALITEMNO.Item To BeInspectedEQUIPMENT IS NOTREADY/AVAILABLE IF:Procedures