TM 5-3740-218-13&PTable 2-4. Operator Level PMCSNOTE: Within designated interval, these checks are to be performed in the order listed.B-BeforeD-DuringA-AfterBDA1•Engine OilAdd oil as necessary to bringOil level low.Levellevel to upper limit of oil fill.Use SAE 10W-40 (item 40,Appendix E).WARNINGGasoline vapor is highlyflammable. Do not fill gastank while engine isrunning. Refuel only in awell-ventilated area.Serious personal injurycould result if fuel ignites.2•Gas Tank:Check level; fill if necessary withLevel too low toregular gasoline (item 19,complete mission.Appendix E). Check fuel filter;remove and clean if necessary.NOTEEnsure 3/4-in. gate valve isclosed before fillinghydraulic reservoir.3•HydraulicCheck fluid level; fill if necessaryLevel not at sightReservoirwith Shell-Tellus 68 or equivalentgage.(item 10, Appendix E).2-9INTERVALITEMNO.Item To BeInspectedEQUIPMENT IS NOTREADY/AVAILABLE IF:Procedures