TM 5-3740-218-13&PHYDRAULIC MOTOR REPAIR (CONT)B.DISASSEMBLYWARNINGDeath or serious injury could result by repeated and/or prolonged breathing and/orskin contact of drycleaning solvent P-D-680. Use in a well-ventilated area. Donot use near open flame or in excessive heat. The flash point of this solvent is100°F-138°F (38°C-59°C).NOTENote location and orientation of parts prior to disassembly to aid in assembly.Parts should be installed to same position from which they were removed.(1)Clean outside of motor with drycleaning solvent (item 59, Appendix E) and dry thoroughly.(2)Scribe matchmarks at junction of body (1) and cover (2) to make sure parts will be installed in same locationand orientation that they are removed.(3)Remove woodruff key (3) and snap ring (4) from drive gear shaft (5).CAUTIONUse soft-jawed vise and light clamping pressure to avoid damaging motor.(4)Secure unit in soft-jawed vise with shaft end down.(5)Remove four bolts (6) and four washers (7) that secure pump body (1) to cover (2).(6)To separate cover (2) from body (1) hold motor, drive end up, and tap end of drive gear shaft with plasticheaded mallet. Do not use metal hammer.CAUTIONUse one hand to support cover from underneath to keep from dropping cover andinternal parts when dowels are removed.5-42