TM 5-3740-214-14
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
NOZZLE PRESSURE BELOW 90 PSI (Continued)
Figure 5-196. Installation of Pressure Gage
(3)
If the gages do not read the same pressure, replace the control panel gage and go to Step 7d.
d.
After replacing the gage, recheck the pressure.
(1)
If the pressure is 90-100 psi, the problem is solved.
(2)
If the pressure is less than 75 psi, go to Step 7c(2).
13. NOZZLE PRESSURE GREATER THAN 100 PSI
Step 1.
Check the separator filter element.
a.
Disassemble the separator.
(1)
Remove the bottom retaining nut.
(2)
Remove the separator body and bottom.
(3)
Remove the filter retaining nut, baffle disc and filter element. Go to Step 1b.
5-179