TM 5-3740-214-14
FORMULATION TANK FILTER MAINTENANCE
Figure 4-99. Formulation Tank Filter
Figure 4-100. Filter Assembly
a. Disassemble filter assembly for inspection.
NOTE
Change filter screen after 100 hours or as necessary.
Clean filter screen as necessary.
Replace gasket with each inspection.
(1)
Remove filter cap and gasket.
(2)
Remove filter screen and inspect it.
b. Inspect filter screen.
(1)
If filter screen is worn or damaged, replace it.
(2)
If filter screen is dirty, clean it with soap and water.
(3)
Replace gasket with each inspection.
c. Assemble filter assembly.
(1)
Insert filter screen into filter body.
4-91