• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
PUMP HEAD - Continued
PUMP HEAD - Continued

Recharging Unit, Carbon Dioxide Reciprocating Pump, Electric Motor Driven, Ac, 115Volt Single Phase, 60 Hz, 1Hp, 12681, 12681-2
Page Navigation
  75    76    77    78    79  80  81    82    83    84    85  
img
.
TM 5-3655-214.13&P
5-5. PUMP HEAD - Continued
LOCATION/ITEM
ACTION
REMARKS
REASSEMBLY
6.
a
Assemble packing (22) packing (21),
valve (20), spring (19) and guide
assembly (17) on cylinder (23) and in-
sert in cylinder (24).
b. Install four flat washers (16), four
lockwashers (15), and four screws (14)
that attach head (23) to cylinder (24).
c.
Install bearing (13), spring (12), retainer
(11) and elbow (10) in head (23).
d. Install packing (9), guide assembly (7),
ring (6), four flat washers (5), four lock-
washers (4) and four screws (3).
e. Install piston (2) and two bushings (1).
INSTALLATION
7.
a
Refer to Chapter 4 and install pump
head.
5-17