PUMP HEAD
PUMP HEAD - Continued

Recharging Unit, Carbon Dioxide Reciprocating Pump, Electric Motor Driven, Ac, 115Volt Single Phase, 60 Hz, 1Hp, 12681, 12681-2
Page Navigation
  74    75    76    77    78  79  80    81    82    83    84  
img
TM 5-3655-214-13&P
5-5. PUMP HEAD - Continued
LOCATION/ITEM
ACTION
REMARKS
DISASSEMBLY
2. Continued
c.
Remove guide assembly (7). Do not
remove bushing (8) until it has been
determined that it is to be replaced.
d. Remove packing (9).
e. Remove elbow (10), retainer (11), spring
(12), and bearing (13).
f.
Remove four screws (14), four lock-
washers (15) and four flat washers (16).
g. Separate head (23) from cylinder (24).
h. Remove guide assembly (17). Do not
remove bushing (18) until it has been
determined that it is to be replaced.
i.
Remove spring (19), valve (20), packing
(21) and packing (22) from head (23).
WARNING
Dry cleaning solvent, P-D-680 or P-S-661, used to clean parts is potentially
dangerous to personnel and property. Use in a well-ventilated area as the
fumes are dangerous if inhaled.  Avoid repeated and prolonged skin
contact. Do not use near open flame or excessive heat. Flash point of
solvent is 100F. - 138F. (38C. - 59C.).
CLEANING, INSPECTION
3.
a
Clean all parts in an approved cleaning
solvent, and dry with a clean cloth or
compressed air.
4.
b. Inspect all parts for defects.
REPAIR
5.
a
Replace defective parts.
5-16