284
AFMAN 24-204(I)/TM 38-250/NAVSUP PUB 505/MCO P4030.19H/ DLAI 4145.3
11 DECEMBER 2001
Table A11.3. Allowable Content of Uranium Hexafluoride (UF6) "Heels" in a Specification 7A Cylinder.
Maximum Cylinder
Diameter
Cylinder
Volume
Maximum
Uranium
235
Enrich-
ment (Weight
%)
Maximum "Heel" Weight Per
Cylinder
UF6
Uranium 235
Inches
Centimeters
Cubic
Feet
L
kg
(lb)
kg
(lb)
5
12.7
0.311
8.8
100.0
0.045
0.1
0.031
0.07
8
20.3
1.359
39
12.5
0.227
0.5
.019
0.04
12
30.5
2.410
68
5.0
0.454
1.0
.015
0.03
30
76
25.64
725
5.0
11.3
25
.383
0.84
48
122
108.9
3084
4.5
22.7
50
.690
1.52
(10 ton)
48
122
142.7
4041
4.5
22.7
50
.690
1.52
(14 ton)
A11.8.1.8. DOT 20PF-1, 20PF-2, 20PF-3 or 21PF-1A, 21PF-1B, or 21PF-2 phenolic-foam insulated overpacks with
snug fitting inner metal cylinders meeting all of the applicable requirements of A3.1, A3.3.7.1, A3.3.7.2, A11.18 and
the following:
-
Handling procedures and packaging criteria must comply with US Department of Energy Report Number
ORO-651 or ANSI N14.1.
-
Quantities of uranium hexafluoride are authorized as shown in table A11.6, with each package assigned a
minimum transport index as also shown.
A11.8.2. Package fissile radioactive materials with radioactive content over A1 or A2 in either:
A11.8.2.1. DOT 6L Metal Packaging.
-
Authorized only for uranium-235, plutonium-239, or plutonium-241, as metal oxide, or compounds that do
not decompose at temperatures up to 149 degrees C (300 degrees F).
-
Radioactive decay heat output must not be more than 5 watts.
-
Radioactive materials in normal form must be packaged in one or more tightly-sealed metal cans or
polyethylene bottles within a DOT 2R containment vessel.
-
Authorized contents are limited per table A11.4:
Table A11.4. Authorized Contents in Kilograms (Kg) and Conditions for Specification 6L Packages.
Uranium-235
Plutonium
(Note 1)
Minimum
Fissile
Transport
Index
Maximum Number
of
Packages
Transported as a
Fissile
Material
Control Shipment
H/X<=3 (Note 2)
3 H/X<=10
H/X<=10
10<=H/X<=20
14
....
3.6 (Note 3)
....
....
2.5
....
2.4
1.3
1.8
80
50
NOTES:
1. Plutonium solutions are not authorized.
2. H/X is the ratio of hydrogen to fissile atoms in the inner containment with all sources of hydrogen in the
containment considered.
3. Volume must not be over 3.6 liters.