BRANCHED ELECTRICAL POWER CABLE ASSEMBLY (DETECTOR POWER).
BRANCHED ELECTRICAL POWER CABLE ASSEMBLY (DETECTOR POWER). - Continued

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  130    131    132    133    134  135  136    137    138    139    140  
img
TM 3-6665-329-13&P
3-51 BRANCHED ELECTRICAL POWER CABLE ASSEMBLY (DETECTOR POWER) (CONT).
(4)
Remove four screws (2), Iockwashers (3) and nuts (4).
Remove terminal board (5).
(5)
Remove wires 11, 13, 14 and 15 from TB1 (5).
(6)
Remove wire 12 from S1 (6).
(7)
Tie lacing and tying tape to one terminal (7).
(8)