TM
3-6665-316-12
4-15.
REPLACEMENT OF RECEIVER IN M43A1 DETECTOR
This
task
covers:
a.
Removal.
b.
Installation.
INITIAL SETUP
No
special
equipment/material
required.
a.
Removal.
1.
Position detector and receiver so that
labels
M43A1
Detector
24
VDC
INPUT and AIR FILTER are toward you.
2.
Turn extender cable connector 1/4 turn counterclockwise and pull
connector (1) from 24 VDC INPUT connector (2). Remove extender cable
connector from BA3517/U Battery Power Cable connector (3).
3.
Screw
protective
cover
(4)
onto
M43A1
Detector
24
VDC
INPUT
connector
(2).
4-26