Installation of Receiver in M43A1 Detector - Continued
Installation of Receiver in M43A1 Detector - Continued

Simulator, Detector Uni Chemical Agent Automatic Alarm, M81 \(Nsn 6665-01-088-4789\)
Page Navigation
  25    26    27    28    29  30  31    32    33    34    35  
img
TM
3-6665-316-12
2-5.
ASSEMBLY AND PREPARATION FOR USE (continued)
13.
While  guiding
M43A1  Interface  Cable  out  thru  bottom  of  receiver  ring,
lower  detector
internal  components  into  receiver  ring.
Be  sure  none
of  M43Al  Interface  Cable  extends  between  case-top  assembly  and
receiver  ring  top  surface.
Be  sure  cable  does  not  interfere
with
electrical
spring  contacts  (8)  or  interface  cable  retainer  (9)  on
inside  of  receiver  ring.
14.
Lower  case-top  assembly  until  bottom  surface  contacts  top  surface
of
receiver  ring,  ensuring  M43A1  Interface  Cable  board  is  properly
seated  in  interface  cable  retainer.
Engage
four  latches  on  receiver  ring  with  four  catches  on  case-top
15.
Push  down  on  four  locking  tabs  to  lock  latches.
assembly.
16.
Push  two  catches  (10)
on
Connector  PI  (7)  on  decoder  printed
wiring
assembly  apart.
Line
up
M43A1  Interface  Cable  Connector  J1
(11)  with
Connector  P1.