Installation of Receiver in M43A1 Detector - Continued

Simulator, Detector Uni Chemical Agent Automatic Alarm, M81 \(Nsn 6665-01-088-4789\)
Page Navigation
  24    25    26    27    28  29  30    31    32    33    34  
img
TM 3-6665-316-12
Remove receiver from transit case.
9.
10.
Position  receiver  (5)  on  flat  surface  so  receiver  ring  is  up,
ex-
tender  is  down,  and  coaxial  connector  (6),  is  to  your  left.
Looking down into receiver ring, locate Connector P1 (7) on decoder
11.
printed wiring assembly.
12.
Position case-top assembly above receiver ring so word CAUTION and
black  radiation  hazard  symbol  are  toward  you.
CAUTION
The  M43A1  Interface  Cable  must  not  interfere
with  electrical  spring  contacts  or  Interface
Cable Retainer on inside of ring or extend
between  case-top  assembly  and  receiver  ring
top surface or damage may result.