TM 3-4230-209-30&P
2-226
REMARKS
ACTION
LOCATION/lTEM
Boiler Assembly/
Remove ignition-combustor cable assembly (6) and nonmetallic
Ignition-combustor cable
grommet (7).
assembly (6)
Nonmetallic grommet (7)
Machine bolts (8)
Internal tooth lock
washers (9)
When handling asbestos material, always wear an air
Combustor assembly (10)
filtering respirator, gloves, and goggles. Wash face and
hands with soap and water before eating or smoking.
Asbestos can cause cancer if handled without protection.
Unscrew and remove eight machine bolts (8) and internal tooth lock
washers (9). Slide out combustor assembly (10).
Remove gasket (11), combustor blower shroud (1 2), and gasket (1 3).
Gasket (11)
Combustor blower
shroud (12)
Gasket (13)