CONTROL PANEL ASSEMBLY. - Continued
ELECTRICAL WIRING. - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  138    139    140    141    142  143  144    145    146    147    148  
img
. .
2-29. ELECTRICAL WIRING.
This task covers:
c. Reassembly
a. Disassembly
b. Repair
INITIAL SETUP
Equipment Condition
Tools and Special Tools
Wiring is removed from the pump unit assembly.
Automotive Maintenance and Repair Field Maintenance
Shop Equipment, Basic, Less Power (SC 4910-95-CL-A31)
Multimeter AN/URM 105C
Materials/Parts
Electrical leads (fig D-63 thru D-79).
REMARKS
LOCATION/lTEM
ACTION
DISASSEMBLY
Electrical Wiring/
Electrical leads
Cut off defective terminal from electrical leads.
Electrical Wiring/
Fabricate new electrical wires. See table below. Refer to wiring schematic
Electrical leads (11 thru 29)
on page 2-129 for wire location. Mark wires according to following table
of connections.
Electrical Wiring/
Electrical leads
Strip 0.375 inch of insulation from electrical leads and crimp terminal lugs
onto exposed wire ends.
TM 3-4230-209-30&P
2-137