TM 10-8415-208-12Table 2-1. Operator Preventive Maintenance Checks and Services for the STEPO-I (Cont)B - Before OperationD - During OperationINTERVALItemItem To BeProceduresEquipment IsNo.InspectedCheck For And Have RepairedNot Ready/BDOr Adjusted As NecessaryAvailable If:40•On/OffOperate the switch to ensure itPump fails to start.Switchis working properly.41••TemperatureRotate valve to ensure it isValve fails toRegulating Valveworking properly.operate.42•AdjustableInspect for missing or brokenBuckles are brokenStrapsbuckles. Ensure proper fit.or missing. Properfit cannot be madeby minoradjustments.43•Inspect webbing for rips orWebbing is ripped ortears.torn.Section III. OPERATION UNDER USUAL CONDITIONS2-7.GENERAL. This section provides instructions for donning, adjusting, operating and doffing the STEPO-Iensemble using the EBA tethered system and the rebreather system under normal operating conditions.2-8.USINGTHESTEPO-IINTHETETHERMODE.2-9.DONNINGTHEENCAPSULATINGPROTECTIVESUITUSINGTHETETHERMODE.a.Refer to items 1 through 12 of Table 2-1 for operator PMCS for the encapsulating protective suit.b.Refer to item 13 of Table 2-1 for operator PMCS for the tether line.c.Refer to items 14 through 26 of Table 2-1 for operator PMCS for the emergency breathing apparatus (EBA).2-12