TM 10-5410-228-24
2.13.31 Receptacle Panel Repair Continued.
(1)
Install utility outlet cable assembly (21) in strain relief (22).
(2)
Secure six receptacle connectors (14) and six gaskets (19) to receptacle panel (4) with 24 screws
(15), 24 flat washers (16), 24 new lockwashers (17) (Item 14, Appx E) and 24 nuts (18).
(3)
If required, cut damaged terminal lug(s) (12) from wires and crimp new terminal lug(s) (12) to
wire. Remove tags from wires.
(4)
Secure 26 terminal lugs (12) and five terminal lugs (13) to six receptacle connectors (14) with
eighteen screws (10) and 36 flat washers (11).
(5)
Install tie-down straps as required.
(6)
Secure receptacle panel (4) to pan (9) with six screws (6), six new lockwashers (7) (Item 17, Appx
E) and
six flat
washers (8).
(7)
Install six caps (20) on six receptacle connectors (14).
NOTE
Secure six cap lanyards under six screws when securing receptacle panel to exterior frame.
(8)
Secure receptacle panel (4) to exterior frame (5) with twenty screws (1), twenty new lockwashers
(2) (Item 17, Appx E) and twenty flat washers (3).
2-276