TM 10-5410-228-24
This task covers:
a. Removal
b. Installation
INITIAL SETUP
Equipment Conditions:
Tools/Test Equipment:
Shop Equipment, Automotive Maintenance and
Power shut off and power panel tagged.
External power cable disconnected.
Shop Equipment: Electrical Equipment
ECV battery ground cable disconnected
(see TM 9-2320-387-24-1).
Materials/Parts:
References:
TM 9-2320-387-24-1
CBPS contains high electrical currents. To prevent electrical shock when working on
electrical system, ensure that power cable is disconnected from power panel and ECV
batteries are disconnected per TM 9-2320-387-24-1. Tag power panel and battery area with
sign that states that the power must remain OFF while work is being performed.
Remove jewelry and observe all safety rules for working around high voltage.
(1)
Loosen two screws (1) and two clamps (2) on hinged cover of AC power line protector (3) and
open hinged cover.
(2)
Remove four screws (4), four lockwashers (5) and four flat washers (6) securing AC power line
protector (3) to LMS (7). Discard four lockwashers (5).
(3)
Tag and remove terminal lugs from terminal board mounted inside AC power line protector (3).
(4)
Pull wires through strain relief connector on bottom of AC power line protector (3).
(1)
Open hinged cover on AC power line protector (3).
(2)
Pull wires through strain relief connector on bottom of AC power line protector (3).
(3)
Install terminal lugs on terminal board mounted inside AC power line protector (3). Remove
tags from wires.
(4)
Secure AC power line protector (3) to LMS (7) with four screws (4), four new lockwashers (5)
(Item 18, Appx E) and four flat washers (6).
(5)
Close hinged cover and tighten two screws (1) and two clamps (2) on hinged cover of AC power
line protector (3).