TM 10-5410-228-24
2.8
UNIT LEVEL TROUBLESHOOTING PROCEDURES Continued.
13. NO AC POWER TO PERIPHERAL OUTLETS J1 THROUGH J4 ON REAR OF LMS WITH ECV
RUNNING INVERTER READINGS NORMAL Continued.
2
1
Turn ECV OFF.
Gain access to receptacle panel per para
Disconnect connector P1 on cable assembly
1A4A10W1 from J5.
Test cable assembly 1A4A10W1 for
continuity per Fig 2-47 pins A to J1-LINE, B
to J1-NEU & C to J1-GND.
Repair or replace cable
No
Yes
assembly 1A4A10W1 per
Does continuity exist?
Gain access to POWER MODE
Set switch to INT.
18 and 19 & 20.
No
Replace POWER
Does continuity exist?
MODE selector switch.
Yes
Do a continuity check of electrical wiring connected
to POWER MODE SELECTOR SWITCH A at pins
Repair wiring as required.
2-52